12.4 RAID12.4.1 Software RAID12.4.1.1 Concatenated Disk Driver (CCD) ConfigurationOriginal work by Christopher Shumway. Revised by Jim Brown.When choosing a mass storage solution the most important factors to consider are speed, reliability, and cost. It is rare to have all three in balance; normally a fast, reliable mass storage device is expensive, and to cut back on cost either speed or reliability must be sacrificed. In designing the system described below, cost was chosen as the most important factor, followed by speed, then reliability. Data transfer speed for this system is ultimately constrained by the network. And while reliability is very important, the CCD drive described below serves online data that is already fully backed up on CD-R's and can easily be replaced. Defining your own requirements is the first step in choosing a mass storage solution. If your requirements prefer speed or reliability over cost, your solution will differ from the system described in this section. 12.4.1.1.1 Installing the HardwareIn addition to the IDE system disk, three Western Digital 30GB, 5400 RPM IDE disks form the core of the CCD disk described below providing approximately 90GB of online storage. Ideally, each IDE disk would have its own IDE controller and cable, but to minimize cost, additional IDE controllers were not used. Instead the disks were configured with jumpers so that each IDE controller has one master, and one slave. Upon reboot, the system BIOS was configured to automatically detect the disks attached. More importantly, FreeBSD detected them on reboot: ad0: 19574MB <WDC WD205BA> [39770/16/63] at ata0-master UDMA33 ad1: 29333MB <WDC WD307AA> [59598/16/63] at ata0-slave UDMA33 ad2: 29333MB <WDC WD307AA> [59598/16/63] at ata1-master UDMA33 ad3: 29333MB <WDC WD307AA> [59598/16/63] at ata1-slave UDMA33
Next, consider how to attach them as part of the file system. You should research both vinum(8) (Chapter 13) and ccd(4). In this particular configuration, ccd(4) was chosen. 12.4.1.1.2 Setting Up the CCDThe driver ccd(4) allows you to take several identical disks and concatenate them into one logical file system. In order to use ccd(4), you need a kernel with ccd(4) support built in. Add this line to your kernel configuration file, rebuild, and reinstall the kernel: pseudo-device ccd 4 On 5.X systems, you have to use instead the following line: device ccd
The ccd(4) support can also be loaded as a kernel loadable module in FreeBSD 3.0 or later. To set up ccd(4), you must first use disklabel(8) to label the disks: disklabel -r -w ad1 auto disklabel -r -w ad2 auto disklabel -r -w ad3 auto This creates a disklabel for ad1c, ad2c and ad3c that spans the entire disk.
The next step is to change the disk label type. You can use disklabel(8) to edit the disks: disklabel -e ad1 disklabel -e ad2 disklabel -e ad3 This opens up the current disk label on each disk with the editor specified by the EDITOR environment variable, typically vi(1). An unmodified disk label will look something like this: 8 partitions: # size offset fstype [fsize bsize bps/cpg] c: 60074784 0 unused 0 0 0 # (Cyl. 0 - 59597) Add a new e partition for ccd(4) to use. This can usually be copied from the c partition, but the fstype must be 4.2BSD. The disk label should now look something like this: 8 partitions: # size offset fstype [fsize bsize bps/cpg] c: 60074784 0 unused 0 0 0 # (Cyl. 0 - 59597) e: 60074784 0 4.2BSD 0 0 0 # (Cyl. 0 - 59597) 12.4.1.1.3 Building the File SystemThe device node for ccd0c may not exist yet, so to create it, perform the following commands: cd /dev sh MAKEDEV ccd0
Now that you have all of the disks labeled, you must build the ccd(4). To do that, use ccdconfig(8), with options similar to the following: ccdconfig ccd0 The use and meaning of each option is shown below:
After running ccdconfig(8) the ccd(4) is configured. A file system can be installed. Refer to newfs(8) for options, or simply run: newfs /dev/ccd0c 12.4.1.1.4 Making it All AutomaticGenerally, you will want to mount the ccd(4) upon each reboot. To do this, you must configure it first. Write out your current configuration to /etc/ccd.conf using the following command: ccdconfig -g > /etc/ccd.conf During reboot, the script /etc/rc runs ccdconfig -C if /etc/ccd.conf exists. This automatically configures the ccd(4) so it can be mounted.
To automatically mount the ccd(4), place an entry for the ccd(4) in /etc/fstab so it will be mounted at boot time: /dev/ccd0c /media ufs rw 2 2 12.4.1.2 The Vinum Volume ManagerThe Vinum Volume Manager is a block device driver which implements virtual disk drives. It isolates disk hardware from the block device interface and maps data in ways which result in an increase in flexibility, performance and reliability compared to the traditional slice view of disk storage. vinum(8) implements the RAID-0, RAID-1 and RAID-5 models, both individually and in combination. See Chapter 13 for more information about vinum(8). 12.4.2 Hardware RAIDFreeBSD also supports a variety of hardware RAID controllers. These devices control a RAID subsystem without the need for FreeBSD specific software to manage the array. Using an on-card BIOS, the card controls most of the disk operations itself. The following is a brief setup description using a Promise IDE RAID controller. When this card is installed and the system is started up, it displays a prompt requesting information. Follow the instructions to enter the card's setup screen. From here, you have the ability to combine all the attached drives. After doing so, the disk(s) will look like a single drive to FreeBSD. Other RAID levels can be set up accordingly. 12.4.3 Rebuilding ATA RAID1 ArraysFreeBSD allows you to hot-replace a failed disk in an array. This requires that you catch it before you reboot. You will probably see something like the following in /var/log/messages or in the dmesg(8) output: ad6 on monster1 suffered a hard error. ad6: READ command timeout tag=0 serv=0 - resetting ad6: trying fallback to PIO mode ata3: resetting devices .. done ad6: hard error reading fsbn 1116119 of 0-7 (ad6 bn 1116119; cn 1107 tn 4 sn 11) status=59 error=40 ar0: WARNING - mirror lost Using atacontrol(8), check for further information:
# atacontrol list
ATA channel 0:
Master: no device present
Slave: acd0 <HL-DT-ST CD-ROM GCR-8520B/1.00> ATA/ATAPI rev 0
ATA channel 1:
Master: no device present
Slave: no device present
ATA channel 2:
Master: ad4 <MAXTOR 6L080J4/A93.0500> ATA/ATAPI rev 5
Slave: no device present
ATA channel 3:
Master: ad6 <MAXTOR 6L080J4/A93.0500> ATA/ATAPI rev 5
Slave: no device present
# atacontrol status ar0
ar0: ATA RAID1 subdisks: ad4 ad6 status: DEGRADED
This, and other documents, can be downloaded from ftp://ftp.FreeBSD.org/pub/FreeBSD/doc/. For questions about FreeBSD, read the documentation before contacting <questions@FreeBSD.org>. |
The FreeBSD Documentation Project Copyright © 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2002, 2003, 2004, 2007, 2006, 2007 The FreeBSD Documentation Project Redistribution and use in source (SGML DocBook) and 'compiled' forms (SGML, HTML, PDF, PostScript, RTF and so forth) with or without modification, are permitted provided that the following conditions are met:
FreeBSD is a registered trademark of Wind River Systems, Inc. This is expected to change soon. 3Com and HomeConnect are registered trademarks of 3Com Corporation. 3ware and Escalade are registered trademarks of 3ware Inc. ARM is a registered trademark of ARM Limited. Adaptec is a registered trademark of Adaptec, Inc. Adobe, Acrobat, Acrobat Reader, and PostScript are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries. Apple, FireWire, Mac, Macintosh, Mac OS, Quicktime, and TrueType are trademarks of Apple Computer, Inc., registered in the United States and other countries. Corel and WordPerfect are trademarks or registered trademarks of Corel Corporation and/or its subsidiaries in Canada, the United States and/or other countries. Sound Blaster is a trademark of Creative Technology Ltd. in the United States and/or other countries. Heidelberg, Helvetica, Palatino, and Times Roman are either registered trademarks or trademarks of Heidelberger Druckmaschinen AG in the U.S. and other countries. IBM, AIX, EtherJet, Netfinity, OS/2, PowerPC, PS/2, S/390, and ThinkPad are trademarks of International Business Machines Corporation in the United States, other countries, or both. IEEE, POSIX, and 802 are registered trademarks of Institute of Electrical and Electronics Engineers, Inc. in the United States. Intel, Celeron, EtherExpress, i386, i486, Itanium, Pentium, and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Intuit and Quicken are registered trademarks and/or registered service marks of Intuit Inc., or one of its subsidiaries, in the United States and other countries. Linux is a registered trademark of Linus Torvalds in the United States. LSI Logic, AcceleRAID, eXtremeRAID, MegaRAID and Mylex are trademarks or registered trademarks of LSI Logic Corp. M-Systems and DiskOnChip are trademarks or registered trademarks of M-Systems Flash Disk Pioneers, Ltd. Macromedia, Flash, and Shockwave are trademarks or registered trademarks of Macromedia, Inc. in the United States and/or other countries. Microsoft, FrontPage, MS-DOS, Outlook, Windows, Windows Media, and Windows NT are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Netscape and the Netscape Navigator are registered trademarks of Netscape Communications Corporation in the U.S. and other countries. Motif, OSF/1, and UNIX are registered trademarks and IT DialTone and The Open Group are trademarks of The Open Group in the United States and other countries. Oracle is a registered trademark of Oracle Corporation. PowerQuest and PartitionMagic are registered trademarks of PowerQuest Corporation in the United States and/or other countries. RealNetworks, RealPlayer, and RealAudio are the registered trademarks of RealNetworks, Inc. Red Hat, RPM, are trademarks or registered trademarks of Red Hat, Inc. in the United States and other countries. SAP, R/3, and mySAP are trademarks or registered trademarks of SAP AG in Germany and in several other countries all over the world. Sun, Sun Microsystems, Java, Java Virtual Machine, JavaServer Pages, JDK, JSP, JVM, Netra, Solaris, StarOffice, Sun Blade, Sun Enterprise, Sun Fire, SunOS, and Ultra are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. Symantec and Ghost are registered trademarks of Symantec Corporation in the United States and other countries. MATLAB is a registered trademark of The MathWorks, Inc. SpeedTouch is a trademark of Thomson U.S. Robotics and Sportster are registered trademarks of U.S. Robotics Corporation. VMware is a trademark of VMware, Inc. Waterloo Maple and Maple are trademarks or registered trademarks of Waterloo Maple Inc. Mathematica is a registered trademark of Wolfram Research, Inc. XFree86 is a trademark of The XFree86 Project, Inc. Ogg Vorbis and Xiph.Org are trademarks of Xiph.Org. Many of the designations used by manufacturers and sellers to distinguish their products are claimed as trademarks. Where those designations appear in this document, and the FreeBSD Project was aware of the trademark claim, the designations have been followed by the ``™'' or the ``®'' symbol. This, and other documents, can be downloaded from ftp://ftp.FreeBSD.org/pub/FreeBSD/doc/. For questions about FreeBSD, read the documentation before contacting <questions@FreeBSD.org>. | ||||
|
Web Design Copyright © 1999-2007. Website designed and Webdeveloped and Website programmed by Web developers and Software programmers. We do excellent webdevelopment and software development in asp and .net c# csharp also. Chrisranjana Software Solutions Pvt Ltd. syndicate rss feed
|
||||